7. Select the AHHC SENSING option.
8. Press the icon that resembles an arrow in a box (A).
The AHHC SENSING menu appears and
fi
ve pages of
information are displayed.
Figure 3.230: John Deere Combine Display
9. Press icon (A) until it reads Page 5 near the top of
the page and the following sensor readings appear:
• LEFT HEADER HEIGHT
• CENTER HEADER HEIGHT
• RIGHT HEADER HEIGHT
A reading is displayed for both left- and right sensor.
On the MacDon header, there are two sensors located
at the back of the
fl
oat module side frame.
Figure 3.231: John Deere Combine Display
10. Ensure header
fl
oat is unlocked.
11. Start the combine and fully lower feeder house to
the ground.
NOTE:
You may need to hold the HEADER DOWN
switch for a few seconds to ensure the feeder
house is fully lowered.
12. Check the sensor reading on the monitor.
13. If the sensor voltage is not within the low and high
limits or if the range between the low and high
limits is insuf
fi
cient refer to
147831
158
Revision A
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Страница 3: ...Declaration of Conformity 147831 i Revision A ...
Страница 4: ...147831 ii Revision A ...
Страница 5: ...147831 iii Revision A ...
Страница 6: ...147831 iv Revision A ...
Страница 8: ......
Страница 10: ......
Страница 34: ......
Страница 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Страница 189: ...OPERATION Figure 3 260 Flow Chart for Setting the Sensitivity of the Float Optimizer 147831 171 Revision A ...
Страница 462: ......
Страница 484: ......
Страница 508: ......
Страница 509: ......