5. Press CAL2 button (G) until lower header light (E) stops
fl
ashing, and release it when the raise header light (D)
begins
fl
ashing.
6. Raise header to its maximum height (ensure the header is resting on the down-stop pads).
7. Press CAL2 button (G) until the raise header light (D) turns off.
NOTE:
The following steps are applicable only to 2005 and newer combines with the Smartrac feeder house.
8. Wait for the HEADER TILT LEFT light (not shown) to start
fl
ashing, and then tilt header to the maximum
left position.
9. Press CAL2 button (G) until the HEADER TILT LEFT light (not shown) stops
fl
ashing, and release button when
the HEADER TILT RIGHT light (not shown) begins
fl
ashing.
10. Tilt the header to the maximum right position.
11. Press CAL2 button (G) until all of the following lights
fl
ash: raise header (D), lower header (E), height auto
mode (A), right header and left header (not shown), and tilt auto mode (F).
12. Center the header.
13. Press CAL1 button (C) to exit calibration and save all values to the memory. All lights should stop
fl
ashing.
Turning off the Accumulator (Gleaner R65/R66/R75/R76 and S Series)
The accumulator will affect the combine’s reaction time and greatly inhibit the auto header height
control’s performance.
Refer to the combine operator’s manual for proper
procedure when turning accumulator off and on. For best
performance, turn the feeder house accumulator off.
NOTE:
The accumulator is located in front of the front left
axle beam.
Figure 3.192: Combine Accumulator
On/Off Switch
A - Accumulator Lever (Off Position)
Adjusting the Header Raise/Lower Rate (Gleaner R65/R66/R75/R76 and S Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to
the combine operator’s manual for updates.
147831
136
Revision A
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Страница 3: ...Declaration of Conformity 147831 i Revision A ...
Страница 4: ...147831 ii Revision A ...
Страница 5: ...147831 iii Revision A ...
Страница 6: ...147831 iv Revision A ...
Страница 8: ......
Страница 10: ......
Страница 34: ......
Страница 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Страница 189: ...OPERATION Figure 3 260 Flow Chart for Setting the Sensitivity of the Float Optimizer 147831 171 Revision A ...
Страница 462: ......
Страница 484: ......
Страница 508: ......
Страница 509: ......