Figure 3.188: Combine Heads Up Display
4. Ensure header
fl
oat is unlocked.
5. Press and hold button (A) on the heads-up display for three seconds to enter diagnostic mode.
6. Scroll down using button (B) until LEFT is displayed on the LCD screen.
7. Press the OK button (C). The number indicated on the LCD screen is the voltage reading from the sensor of the
AHHC. Raise and lower the header to see the full range of voltage readings.
Engaging the Auto Header Height Control (Gleaner R65/R66/R75/R76 and S Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to
the combine operator’s manual for updates.
The following system components are required in order for the auto header height control (AHHC) to work:
• Main module (PCB board) and header driver module (PCB board) mounted in card box in fuse pane module (FP).
• Multi-Function Control Handle operator inputs.
• Operator inputs mounted in the control console module (CC) panel.
NOTE:
In addition to the above components, the electro hydraulic header lift control valve also is an integral part of
the system.
147831
133
Revision A
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Страница 3: ...Declaration of Conformity 147831 i Revision A ...
Страница 4: ...147831 ii Revision A ...
Страница 5: ...147831 iii Revision A ...
Страница 6: ...147831 iv Revision A ...
Страница 8: ......
Страница 10: ......
Страница 34: ......
Страница 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Страница 189: ...OPERATION Figure 3 260 Flow Chart for Setting the Sensitivity of the Float Optimizer 147831 171 Revision A ...
Страница 462: ......
Страница 484: ......
Страница 508: ......
Страница 509: ......