3.12
Upper Cross Auger (UCA)
The UCA (A) improves delivery of very bulky crops across
the header.
Beater bars (standard on 45-foot headers) assist in
delivering material through the header opening, but are
removable if wrapping occurs.
IMPORTANT:
If the UCA is installed, a case drain line must be installed
on the right-hand draper motor. See your MacDon Dealer
for details.
Figure 3.334: Upper Cross Auger
3.12.1
Removing Beater Bars
Beater bars are standard on 45-foot header only.
DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
1. Lower the header to the ground, stop the engine, and
remove the key from the ignition.
2. Remove bolts (A) securing the beater bars (B) and
clamps (C) to the auger tubes, and remove the beater
bars and clamps.
IMPORTANT:
Lift reel and engage safety props if working on
double reel header.
Figure 3.335: Beater Bars
3.12.2
Installing Beater Bars
Beater bars are standard on 45-foot header only.
DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
147831
206
Revision A
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Страница 3: ...Declaration of Conformity 147831 i Revision A ...
Страница 4: ...147831 ii Revision A ...
Страница 5: ...147831 iii Revision A ...
Страница 6: ...147831 iv Revision A ...
Страница 8: ......
Страница 10: ......
Страница 34: ......
Страница 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Страница 189: ...OPERATION Figure 3 260 Flow Chart for Setting the Sensitivity of the Float Optimizer 147831 171 Revision A ...
Страница 462: ......
Страница 484: ......
Страница 508: ......
Страница 509: ......