VERIFICATION STATION
Logicube OmniClone® Xi User’s Manual
66
2. Remove the drive and any cables from the
Standard Drive Station.
3. Loosen the two thumb-screws located on either
side of the Drive Station.
4. Pull straight up on the thumb-screws, the Drive
Station should come right out.
5. Insert the Verification Station into the now-empty
slot. Make sure that the IDE-style connector on
the bottom of the Combo Station lines up with
the socket inside the OmniClone® Xi unit.
6. Tighten the two thumb-screws on either side of
the Verification Station.
7. Repeat Steps 1
– 6 for any other Verification
Stations that need to be installed.
NOTE:
The Verification Stations can only be
used in the Target positions on the OmniClone®
Xi.
Generating the Master MD5 Hash Value
The Logicube Verification Stations compare each
drive with a “Gold Master” MD5 Hash Value. This
value is calculated from the Master drive, and
stored in a file called “checksum.txt” that resides on
the Compact Flash (CF) card of the OmniClone Xi.
After a Mirror Cloning session, the Target drives
should all have MD5 values that match the Gold
Master MD5 hash value.
There are different ways of generating the MD5
Hash Value of the Gold Master drive:
Use the Logicube OmniClone Xi with
Verification Stations to generate the Gold
Master MD5 hash value. This method
automatically stores the MD5 checksum
value on the CompactFlash card of the
Logicube OmniClone Xi. This is the
recommended way of generating the MD5
Hash Value of the Master drive.
Note:
Please refer to
“How to use the
Verification Station”
further in this section
for step-by-step procedures on how to
generate the Master MD5 hash value using
the Logicube OmniClone Xi.