Logicube OmniClone® Xi User’s Manual
7
2. Getting Started (Fast Start)
Applying power to the Logicube OmniClone Xi
The Logicube OmniClone Xi is able to detect whether
an IDE (PATA) or Serial ATA (SATA) drive is attached
to the Master or Target positions. The unit is capable
of cloning to/from a SATA drive to an IDE drive and
vice versa (as well as IDE to IDE and SATA to SATA).
NOTE
: Never attach both an IDE and SATA drive to
the same drive position. The unit can only handle one
drive on each position.
Before applying power perform the steps listed below.
Connecting Parallel (IDE, EIDE, UDMA) Drives
1. Locate the Master position on the top of your
OmniClone Xi unit. You will notice three
connections: One for a flat cable (the IDE/PATA
drive data cable) and another for a small drive
power cable. Above is the third connector for the
Serial ATA cable.
Note
: The drive that is cloned from is always
referred to as the
Master
drive and the drives
that are cloned to are always referred to as the
Target
drives.
2.
Attach the 5” UDMA cable and the drive Power
cable to the connectors.
3. Connect the Master hard drive to the cables and
verify that the drive’s jumper is set to Single
Master.
4. Follow steps 1
– 3 to attach drives to the Target
positions of the Logicube OmniClone Xi.
5. Connect the AC Power Cord to the back of the
Logicube OmniClone Xi and power-up the unit. In
2
– 3 seconds, the main “Splash” screen appears.