USER REPLACEABLE HARDWARE
Logicube OmniClone® Xi User’s Manual
63
attached to the head. DO NOT pull on the cable
itself as this will diminish cable life.
Power cables
– Remove the cable from the drive
by gripping the yellow plastic head firmly and pulling
straight out. Do NOT pull on the wires as this will
damage the cable.
SATA Cables
– Remove the cable from the drive
by gripping the black plastic head firmly and pulling
straight out. DO NOT twist or pull by the cable as
this will shorten cable life.
Drive Stations
The “Drive Stations” of the OmniClone Xi refer to
the connection plates of each Master and Target
position. These plates are very rugged and able to
withstand thousands of cloning sessions. However,
damaged or incorrectly connected drives can
damage the Drive Station. When this occurs, the
station can be easily replaced by the user.
Replacement Drive Station Modules are available
from Logicube. Please contact Logicube Sales for
more information.
Removal of a Drive Station
1. Turn off the power to the unit and unplug the
power supply cord.
2. Remove the drive and any cables from the
non-functional Drive Station.
3. Loosen the two thumb-screws located on
either side of the Drive Station.
4. Pull straight up on the thumb-screws, the
Drive Station should come right out.
Installation of a Drive Station
1. Turn off the power to the unit and unplog
the power supply cord.
2. Insert the Drive Station, making sure the
50-pin male connector on the DriveStation
aligns with the 50-pin female connector on
the OmniClone Xi board.
3. Tighten the two thumb-screws located on
either side of the Drive Station.
4. Test the new Drive Station by attaching a
drive to it and performing a
Drive Info
by
tapping
Drives
from the main menu.
Содержание Omniclone Xi
Страница 13: ...INTRODUCTION Logicube OmniClone Xi User s Manual 5 Figure 1 Logicube OmniClone Xi...
Страница 14: ......