THE SERIAL LINK OPTION
Logicube OmniClone® Xi User’s Manual
54
Serial Link Setup Step-by-Step
1. Verify that the Serial Link option is enabled
on the OmniClone Xi by checking the About
Screen.
2. Power the OmniClone Xi unit OFF.
3. Connect one end of the Serial Link cable to
the ps/2 port on the OmniClone Xi.
4. Connect the opposite end of the cable to the
serial port of a PC running Windows XP or
later.
5. On the PC, bring up Hyper Terminal by
going to Start > All Programs > Accessories
> Communications > Hyper Terminal.
Note:
Microsoft stopped including Hyper
Terminal in some versions of Windows Vista
and all versions of Windows 7. Any terminal
program can be used to use the Serial Link
option. The rest of these instructions refer to
Hyper Terminal in Windows XP. If you are
using different software, please consult the
software’s user’s manual for information on
how to configure the following settings.
6. Choose "File - New Connection" or follow
the connection wizard if it comes up
automatically.
7. Name the Connection "OCXI_01" and
choose an icon.
8. In the next screen, choose the highest COM
port. You can also refer to Windows Device
Manager to determine the correct port.
9. In the next screen, set Bits Per Second:
9600, Data Bits: 8, Parity: None, Stop Bits: 1
and Flow Control: Xon/Xoff.
10. In the HyperTerminal Window, be sure to
Save the connection as "OCXI_01".
11. Power up the OmniClone Xi unit. A
“welcome message” will appear on the
Hyper Terminal window.
12. Before entering commands, make sure that
the CAPS LOCK key is engaged on the PC.
All commands are upper case.
NOTE:
Multiple OmniClone Xi units can be
controlled from the same PC provided that it
has enough Serial ports to connect the
different units. Since each unit will be on a
separate COM port, just create a new Hyper
Terminal connection for every OmniClone