52
ZENIT
YARN STRUCTURE
Coarse Yarn Limitation
If a diameter base higher than 868 mV is determined during
adjustment, the class settings are tightened to the next class
below the coarse yarn boundary line, if required and if already
switched on. (Class Settings, Figure 1 and 2)
If the yarn cannot be cleared in this manner, the classes have
to be switched off completely in the respective area. (Marked
grey in Figure 3)
Figure 1
Figure 2
Figure 3