ZENIT
37
BASE SETTINGS
Special Functions
Splice Check
ON / OFF
Switching the splice check on and off.
Note :
If the
Splice Check
is switched off, the
Splice
menu area
in the
Yarn Structure
menu is disabled and the splice curve is
no longer displayed.
Reduction
After an initial start or adjust, many cuts can be registered
with very sensitive settings in the yarn count channel or fault
cluster channel. To avoid these cuts, the sensitivity can be
reduced as required, i. e. the diameter limit value can be in-
creased by 0% to 250%.
The reduction is automatically canceled for every spindle af-
ter approx. 12 km of wound yarn.
The
OFF
setting switches off the yarn count channel as well as
the cluster channel during the first approx. 12 km.
When an Spindle Adjust is performed for a spindle, this change
of sensitivity also becomes active for approximately 12 km.
Reduction for a Cone Change
At a cone change, the limits for the long fault length (LL) and
the thin place length (-L) are set to 2 m. The diameter limits
for long faults (DL) and diameter decrease (-D) are less sensi-
tive according to the set reduction.
When the reduction is switched off, the long fault channel
as well as the thin place channel are switched off for the
first 12 m.
Note :
The yarn count channel and the foreign matter clearing
are not active during the first 10 m after every cone change,
inde pendent of the set reduction.
F Sensor
The F-Sensor for this group can be switched off when foreign
matter clearing is not to be active on a group. The
F-Mode
becomes inactive and the
Foreign Matter
menu as well as the
F-Clearing Data
are no longer displayed.