ZENIT
75
SERVICE FUNCTIONS
CLEARER COMPONENTS AND FUNCTION
Central Unit LZE-III
Connection at the front side
USB 2.0 port for transfer of reports to a PC / printer.
Connections at the back side
The LZE-III has an internal uninterruptible power supply (UPS). Write operations in progress to the Compact Flash board are
terminated normally and no new write operations begun during interruption. The buffer capacity of the UPS is sufficient to op-
erate the LZE-III for a maximum of 5 seconds with the monitor switched off. During current interruption, the monitor and the
USB port are switched off. Touchscreen entries are not possible during this time. Central unit LZE-III starts normally when the
regular power supply is available again.
Marking
Type
Description
LAN 0 / LAN 1
RJ45
LAN 10 / 100 / 1000
USB 0 / USB 1
USB 2.0
USB Port
LOEPFE 1
Sub-D, 9 pol plug
2/5-wire-bus
HDD
LED red
Compact Flash drive active
PWR
LED green / red
Power supply OK
Reset
Micro Switch
Automatic restart of central unit.
Caution: Saved data will be lost!
AMP Contact Pin 6.3 mm
PE Protective Earth (Ground)
This separate mass point must be connected
with the machine mass.
Power
Sub D PSC
Orion / Polar
Power supply 24 V DC (direct current)
Contact 1 – 0 V DC (brown)
Contact 2 not connected
Contact 3 + 24 V DC (white)
M21C / Espero i
Espero Nuovo
Smaro / Spero
AC 238 / EJP 438
DTM 439 / VJ Excello
Connected to Power Supply Unit
(Power ON/OFF)
Micro Switch
Shut down to standby mode (5V) and restart of central unit.
!
!
Содержание YarnMaster Zenit
Страница 1: ...YARNMASTER ZENIT Instruction Manual LZE 044843 003en...
Страница 2: ......
Страница 4: ......
Страница 82: ...w...