DIAGNOSIS
Diagnosis
AWE Zenit State / Adjust Parameters
AWE Command
This information is used exclusively by the service techni-
cians or trained personnel.
!
Incorrect commands can have severe consequences
for the clearer function!
Diameter Base
(Spindle)
In
Diameter Base
, the determined value is automatically dis-
played after an Adjust process. This value corresponds nor-
mally to the average yarn signal of the spindle.
!
This value should be changed manually only in special
cases!
Fine Adjust Diff
Deviation in percent of the yarn diameter averaged over all
spindles from the basic value (adjustment value).
!
A continuous deviation of this indication means a
yarn count deviation!
Spindle Adjust
When replacing an evaluation unit (AWE) or a sensing head
(TK), a reset must be performed on the AWE. Additionally,
an
Spindle Adjust
must
always
be performed on this winding
unit. The yarn reference value of the first 80 m yarn is mea-
sured and stored.
•
Tap the
Start
button
•
Start the respective spindle.
The display on the button switches to
Stop
. If the adjustment
was successfully completed, Start is displayed again.
!
The wound yarn (80 m) could still have faults since
the clearing is not active during the Adjust process.
Cut Declaration
See
Monitoring Data
.