ZENIT
67
REPORTS AND DIAGNOSIS
Technical Alarms
Message
Explanation / Cause
Action
Adjust failed, please repeat
Adjust.
Adjustment was not possible
on any of the pilot spindles.
Select different pilot spindles and repeat
adjustment.
Replace TK / AWE and repeat adjustment.
Coarse yarn: Settings
CHANGED for group x!
Diameter basis > 868 mV
Reduced diameter limit value in the neps channel as
well as stricter class settings in the neps area.
Check the settings in the neps area.
If necessary, switch off the N channel (OFF).
If necessary, completely switch off the
classes in the neps area.
Communication Locked
Break or short-circuit in the communication lead.
Defective AWE.
Locate defective AWE:
Un plug one AWE after the other.
F Mode changed, Adjust
required on group x.
The F mode setting was changed
(Basic settings menu).
Start adjustment for this group.
Incompatible TK!
TK Zenit C in group with TK Zenit B or
vice versa.
Exchange TK.
Adapt spindle range to group.
Interface for SPECTRA detect
ed. Set switch on AWE Inter
face to ZENIT !
False clearer system assigned.
Perform a factory reset
Select the Zenit clearer system.
Mismatch of detected interface
type. Consult the manual!
Wrong clearer system assigned.
Perform the factory reset and
select the Zenit clearer system.
Pilot spindle x : D Adjust failed
Adjustment was not possible on one of the pilot
spindles.
Select a different pilot spindle and repeat
adjustment.
Replace TK / AWE and repeat adjustment.
Pilot spindle x : Diameter out
of range
Adjustment was not possible on one of the pilot
spindles.
Select a different pilot spindle and repeat
adjustment.
Replace TK / AWE and repeat adjustment.
Pilot spindle x : F Adjust failed
Adjustment was not possible on one of the pilot
spindles.
Select a different pilot spindle and repeat
adjustment.
Replace TK / AWE and repeat adjustment.
Reduced AWE functionality!
Functionality of whole group
reduced!
Older AWE version.
The AWE version has fewer functions than the rest
of the group.
Exchange AWE.
Spindle range changed,
Adjust cancelled on group x.
Spindle range was changed
group-wide.
Repeat adjustment for this group.
Spindle x : AWE Locked
System-dependent AWE alarm
Perform Reset AWE.
Replace AWE and perform Reset AWE.
Spindle x : AWE System Error
Electrical interference
Defective AWE
Perform Reset AWE.
Replace AWE and perform Reset AWE.
Spindle x : AWE 800 or
AWE Spectra on Zenit Line
False AWE type
Locate and exchange AWE
Spindle x : D Adjust Error
Optics for scanning of the yarn diameter dirty.
Incorrect zeroing.
Yarn count outside of sensing head range.
Clean optic.
Repeat adjust.
Check yarn count.
Use different spindles for adjust.
Start spindle briefly.
Replace TK / AWE and perform Reset AWE.
Содержание YarnMaster Zenit
Страница 1: ...YARNMASTER ZENIT Instruction Manual LZE 044843 003en...
Страница 2: ......
Страница 4: ......
Страница 82: ...w...