ZENIT
45
YARN STRUCTURE
!
Faults / Observation Length
These two settings define the limits of the accumulation den-
sity to the length unit for the faults which are above the clus-
ter curve.
When the set number of faults is exceeded within the set ob-
servation length, the spindle is blocked after the set number
of repetitions.
Act. Faults
All events (irregularities) above the cluster curve are continu-
ously count ed via the set
Window Length
(
Base Settings
menu).
The number obtained in this manner is converted to the ob-
servation length and displayed as setting support in
Act. Faults
.
The set number of faults must be signifi cantly
higher than the displayed events (Act. Faults).
If the number of counted events is 10% higher
than the set number of faults, cluster cuts can oc-
cur more frequently. (If necessary, increase the
«Diameter» value).
Diameter
Yarn diameter setting range:
Short (DS)
1.10 –
4.00
Long (DL)
1.04 –
2.00
Thin (-D)
- 6% – - 60%
The setting range refers to the normal yarn diameter. For ex-
ample, if the same setting is chosen as for the channel set-
ting (DS / DL / -D), it corresponds to the normal clearing curve
set. The number 1.0 would correspond to the base, viz. the
normal yarn diameter.
Length
Reference length setting range:
Short (LS)
1.0 cm – 10 cm
Long (LL)
6.0 cm – 200 cm
Thin (-L)
2.0 cm – 200 cm