SAFETY INSTRUCTIONS
!
!
!
!
Operational Notes
This yarn clearing equipment must only be installed, initiated
and operated by trained personnel. Improper operation of the
equipment could cause hazards.
In accordance with 2006/42/EC, 2006/95/EC, 2004/108/EC
this yarn clearing installation should only be operated with the
covers closed (cooling, fire protection, contamination, spark
interference etc.)
This yarn clearing equipment must only be operated with
the standard power supply (voltage/cycles) with ground con-
nection.
AC 110V
60Hz
3.15 A
-15%/+20%
AC 230V
50Hz
3.15 A
±15%
As per other information by the machinery manufacturer,
how ever, with ground connection and with an isolation
trans former which complies with the requirements of DIN
EN 61558.
The ON/OFF switch does not disconnect the equipment
from the mains voltage! Failure to comply with this
warning can result in death or severe injuries.
Before opening, modifying or completing the equipment,
dis connect the mains plug from the grounded power supply
socket or turn off the master switch of the winding machine.
This yarn clearer system may be connected to the power sup-
ply only after installation of all front panels, plug-in boards and
provided covers, in particular of the central unit.
Under certain conditions, high temperatures may occur at the
power print of the control station. Check the temperature be-
fore touching the cooling rips.
The knives at the sensing heads are automatically activated.
Beware of touching the knives, you could be injured.
Electronic components and assemblies (printed circuit
boards) are endangered by electrostatic charges!
Be-
ware of touching the soldered connectors, pin contacts, print-
ed circuits or electronic components before they have been
discharged statically. Hold the units at the periphery only.