34
ZENIT
BASE SETTINGS
Base Settings
Repetitions
It must be defined how often the exceeding of the limiting
value is tolerated (0 – 9).
Murata 21C
In
Off Count
and
Short Off Count
, the maximum
number of repetitions (9) is automatically set and cannot be
changed. Cycle repetitions and alarms are processed by the
winding machine.
If the limiting value is exceeded, the spindle is blocked after
the set number of repetitions.
The 7-Segment Display
at the sensing head blinks con-
tinuously. The reason for spindle blocking is displayed on
the sensing head.
The spindel is in alarm. Reset spindle alarm: see page 69.
By the constant communication between the evalua tion unit
computer and the spindle computer, the specified fault length
(80 m max.) is drawn from the cone.
NSLT Startup / F Startup / P Startup
With these settings, the bobbins with frequent faults can be
detected. If frequent startup cuts in the NSLT channel or for-
eign matter classes are registered, the spindle will be blocked
after the number of repetitions set.
Содержание YarnMaster Zenit
Страница 1: ...YARNMASTER ZENIT Instruction Manual LZE 044843 003en...
Страница 2: ......
Страница 4: ......
Страница 82: ...w...