ZENIT
31
GROUP
Samples
TK YM Zenit C
TK YM Zenit A/B
Sections
Groups
Zenit C
Zenit FC
Zenit FPC
Zenit
Zenit F
Zenit FP
Section 1 01-60 / AWE Zenit L2 / TK Zenit FPC
Group 1 01-60 / TK Zenit FPC
(subdivision possible)
Section 1 01-60 / AWE Zenit L2 / TK Zenit FC
Group 1 01-60
/ TK Zenit FC
(subdivision possible)
Section 1 01-60 / AWE ZenitL2 / TK Zenit C
Group 1 01-60 / TK Zenit C
(subdivision possible)
Section 1 01-40 / AWE Zenit L2 /
TK Zenit FPC
Section 2 41–60 / AWE Zenit L2 /
TK Zenit FC
Group 1 01-60 /
TK Zenit FC
If a group is created over two sections with different sensing head
types, the functionality of the whole group is equivalent to the
lowest TK type. The complete working range looses the capability
to clear synthetic foreign matter (P).
Error message:
“Reduced TK functionality! Functionality of whole
group reduced!”
To maintain the functionality of all sensing heads, at least one
separate group per section must be created:
Group 1 01-40 /
TK Zenit FPC
(subdivision possible)
Group 2 41-60 /
TK Zenit FC
(subdivision possible)
Section 1 01-40 / AWE Zenit L2 /
TK Zenit FC
Section 2 41-60 / AWE ZenitL2 /
TK Zenit F
Group 1 01-60 /
INVALID!!!
If a group is created over two sections with different sens
ing head types (A (UR), B, or C), the functionality of this
group is not ensured!
Error message:
“Incompatible TK!”
To maintain the functionality of all sensing heads, at least one
separate group per section must be created:
Group 1 01-40 /
TK Zenit FC
(subdivision possible)
Group 2 41-60 /
TK Zenit F
(subdivision possible)