Within a module you can access the I/O data, parameter data and diagnostic data via index
numbers. Under PROFINET the index numbers are summarised in the following areas:
0x0000 ... 0x7FFF: Manufacturer-specific index numbers
0x8000 ... 0xF7FF: Standard index numbers of PROFINET.
Information on this can be found in the PROFINET specification. There, the "index" is also called
"data record". In the following, all supported index numbers are listed.
Index
Description
Readable index numbers
0x0000
Read DS 0x00 diagnostic data
0x0001
Read DS 0x01 diagnostic data
0x007D
Read all parameter data
0x007E
Read DS 0x00 of the parameter data
0x007F (only I/O compound modules)
Read DS 0x01 of the parameter data
0x0080 . 0x0090 (only I/O compound modules)
DS 0x80 . Read DS 0x90 of the parameter data
0x8000 / 0x8001 / 0x800A / 0x800B / 0x800C /
0x8010 / 0x8011 / 0x8012 / 0x8013 / 0x801E /
0x802A / 0x802B / 0x802C / 0x802D / 0x802F /
0x8030 / 0x8031 / 0x8050 / 0x8051 / 0x8052 /
0x8053 / 0x8054 / 0x8060 / 0x8061 / 0x8062 /
0x8070 / 0x8080 / 0x8090
See PROFINET specification
0x8028 (only I/O compound modules)
Read input data of a sub-slot
0x8029 (only I/O compound modules)
Read output data of a sub-slot
0xAFF0
Read I&M 0 (serial no., name, SW/HW version)
0xAFF1 (only PROFINET bus coupler9)
Read I&M 1 (designation and mounting place)
0xAFF2 (only PROFINET bus Buskoppler9)
Read I&M 2 (date of installation)
0xAFF3 (only PROFINET bus Buskoppler9)
Read I&M 3 (comment)
0xC000 / 0xC001 / 0xC00A / 0xC00B / 0xC00C /
0xC010 / 0xC011 / 0xC012 / 0xC013 / 0xE000 /
0xE001 / 0xE002 / 0xE00A / 0xE00B / 0xE00C /
0xE010 / 0xE011 / 0xE012 / 0xE013 / 0xE030 /
0xE040 / 0xE050 / 0xF000 / 0xF001 / 0xF00A /
0xF00B / 0xF00C / 0xF010 / 0xF011 / 0xF012 /
0xF013 / 0xF020 / 0xF80C / 0xF820 / 0xF821 /
0xF830 / 0xF831 / 0xF840 / 0x8041 / 0xF842
See PROFINET specification
Writable index numbers
0x007D
Write all parameter data
0x007E
Write DS 0x00 of the parameter data
0x007F (only I/O compound modules)
Write DS 0x01 of the parameter data
0x0080 . 0x0090 (only I/O compound modules)
Write DS 0x80 .DS 0x90 of the parameter data
0xAFF1 (only PROFINET bus coupler9)
Write I&M 1 (designation and mounting place)
0xAFF2 (only PROFINET bus Buskoppler9)
Write I&M 2 (date of installation)
0xAFF3 (only PROFINET bus Buskoppler9)
Write I&M 3 (comment)