5
CANopen communication
5.12
Parameterising the time stamp
155
Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.12
Parameterising the time stamp
5.12.1
2 digital inputs with time stamp function - EPM-S207
Parameter data
5.12.2
2 digital outputs with time stamp function - EPM-S310
Parameter data
Index/subindex
Name
Description/value
Lenze
I-3100/x
Length - process
image input data
Length of input data (backplane bus communication); the
values are specified by the system. Other values are not
permissible.
0x14 or
0x3C (fix)
I-3101/x
Length - process
image output data
Length of output data (backplane bus communication); the
values are specified by the system. Other values are not
permissible.
0x00 (fix)
I-3102/x
Input delay DI1
0x00 = 1
s
0x02 = 3
s
0x04 = 10
s
0x07 = 86
s
0x09 = 342
s
0x0C = 273
s
No other values are permissible.
0x02
I-3103/x
Input delay DI2
0x02
I-3104/x
Edge 0-1 at DIx
Time stamp entry on rising edge
Bit 0: DI1 (0: inhibit, 1 = enable)
Bit 1: DI2 (0: inhibit, 1 = enable)
Bits 7 ... 2: reserved
0x00
I-3105/x
Edge 1-0 at DIx
Time stamp entry on falling edge
Bit 0: DI1 (0: inhibit, 1 = enable)
Bit 1: DI2 (0: inhibit, 1 = enable)
Bits 7 ... 2: reserved
0x00
I-3106/x ...
I-3129/x
Reserved
Index/subindex
Name
Description/value
Lenze
I-3100/x
Length - process
image input data
Length of input data (backplane bus communication); the
values are specified by the system. Other values are not
permissible.
0x14 or
0x3C (fix)
I-3101/x
Length - process
image output data
Length of output data (backplane bus communication); the
values are specified by the system. Other values are not
permissible.
0x00 (fix)
I-3102/x ...
I-3129/x
Reserved