diamond - User Manual
Version: 8.0.0/1
Exported on: 24 October, 2023
140
/
228
The integrated loudness measurement is always on, for all outputs, once the GUI App starts. To comply with the ITU
standard, the signal's loudness must be greater than -70 LUFS before an integrated measurement is registered. From
hereon, the reading will continue to update over time and represents the average loudness of the output since the start.
The integrated loudness measurement for all outputs can be reset by touching the LUFS value (on any meter) for more than
one second.
Compliance with Metering Standards
Version 1.0 of the diamond standard configuration is compliant with EBU meters and levels. Other variants will follow to
support SMPTE and other regions. The table below describes the relevant parameters.
diamond Standard Configuration
Europe
North America
Standard
EBU
SMPTE
PPM meter scale
dBFS
dBFS
PPM mark low
-18
-20
PPM mark high
-9
-3 (+17 dBR)
Loudness meter (channel, access and slots)
LU EBU +9 (short)
LU EBU +9 (short)
Loudness value LUFS (slots)
LUFS -23 (integrated)
LUFS -23 (integrated)
Relative System level (OAD)
-36
-38
Analog Ref Level (OAD)
18
24
Operating Level (analog)
0 dBU
+4 dBU
Operating Level (digital)
-18 dBFS
-20 dBFS