Troubleshooting
162
Machine
makes a noise
while running
Discharge bushing makes contact with
the spreading disc
Please contact your dealer
Spreader put down with filled hopper
Repair the machine.
Set dosing mechanism and discharge
point again
141,
144
Spreading disc hidden/ out of balance
Check the spreading discs for damage
and for the presence of all the vanes
66
Build-up of fertiliser at the agitator and/or
spreading discs
Remove the fertiliser.
Clean the machine well after each use.
124
Powerful vibra-
tions percepti-
ble
Shut down the PTO shaft immediately!
Attend to the problem to prevent damage
Great imbalance in the spreading discs
Check the vanes and spreading discs
66
Bent agitator axle or damaged agitator
Replace the agitator axle or the agitator
PTO shaft working angle out of working
reach
Limit the working angle to a maximum of
30º
52
Alarm on the
control box
screen
The control system cannot perform re-
quested function correctly
Consult meaning and advice in the soft-
ware's instruction manual
The external
system is not
communicat-
ing with the
control box
RS232 plug does not have the correct
connection on the side of the control box
for the signal from the external system
Check and modify the plug pin occupation
on the side of the control box, see user's
manual for control box and external sys-
tem
The control box and external systems are
not communicating with each other in the
same language
Check the control box settings by means
of the external system data, see user's
manual for the control box, tractor, Tellus
and external system
Application rate control by means of an
external signal is not connected
Switch on the external signal reception
External system not switched on or incor-
rectly set
Check external system operation
Spreader does
not appear on
the screen
Control box displays another system
Press the switch key to choose the
spreader display
33
Spreader ISO plug not connected
Connect the spreader ISO plug
57
Power supply to the spreader and/or con-
trol box interrupted
Check the electrical cables and fuses
Problem
Possible cause
Solution
Pag
e
Содержание Exacta-TL-GEOSPREAD GS3
Страница 6: ...Preface 6 ...