Use in the field
120
These failures are probably caused by one of the following:
•
a hard object blocks the agitator,
•
a hard object or a large piece of fertilizer is (partially) blocking the
supply from flowing to the agitator,
•
a hard object or a large piece of fertilizer is (partially) blocking
fertilizer from flowing through the dosing opening or discharge
bushing,
•
crushed and/or damp fertilizer forms an encrusted layer beneath
the agitator and blocks the flow through the dosing openings,
•
a lump of damp fertilizer has formed in the discharge bushing and
is blocking flow from the discharge bushing opening. This happens
especially when the spreader has not been thoroughly cleaned
after it was last used.
I
NDICATION
Most types of fertilizer attract water and can thereby form large
chunks. These chunks can block the spreader or distort the spreading
pattern.
•
When working under moist conditions, use a hopper cover that
closes well.
•
Do not spread without a hopper cover under moist conditions.
•
Never leave the fertilizer for a long period of time in the spreader.
Chunks can also be formed through moisture in the air.
•
Always clean the spreader well after use, including the dosing
openings and the discharge bushings.
Working method
I
NDICATION
Do not place the machine on the ground. Placing a filled machine on
the ground damages the structure!
\
WARNING
Handle with care
Cautiously approach the machine and handle with care. There
could be hot or live parts! Contact with these materials could
cause physical injury.
To find the cause of the failure or stoppage and solve it as far as
possible, proceed as follows.
Disconnect the PTO shaft immediately!
Switch off the electronic control system.
Release the pressure from the hydraulic system.
Place all controls in their neutral or park position.
Switch off the tractor,
remove the key from the ignition,
engage the parking brake of the tractor.