![Krone BiG Pack 870 HDP XC Скачать руководство пользователя страница 314](http://html1.mh-extra.com/html/krone/big-pack-870-hdp-xc/big-pack-870-hdp-xc_original-operating-instructions_2004796314.webp)
22
Malfunction, cause and remedy
22.1
Malfunction in the electrics/electronics
314
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
522560-
FMA1
Force measurement amplifier (FMA) for baling force regulation
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522561-
FMA1
Force measurement amplifier (FMA) for baling force regulation
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
The wiring to KMC is faulty.
Check wiring for damage.
One or more sensors/actuat-
ors connected to the voltage
group are defective.
There is an overview of the position of the sensors,
actuators and control units in the circuit diagram,
Check sensor and wiring for damage,
.
The control unit is defective.
Replace the control unit.
522562-
FMA1
Force measurement amplifier (FMA) for baling force regulation
Possible cause
Remedy
FMI 31: The condition has been fulfilled.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522563-
FMA1
Force measurement amplifier (FMA) for baling force regulation
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
The wiring to KMC is faulty.
Check wiring for damage.
One or more sensors/actuat-
ors connected to the voltage
group are defective.
There is an overview of the position of the sensors,
actuators and control units in the circuit diagram,
Check sensor and wiring for damage,
.
The control unit is defective.
Replace the control unit.
522565-
FMA2
Force measurement amplifier (FMA) for bale scale
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.