Malfunction, cause and remedy
22
Malfunction in the electrics/electronics
22.1
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
287
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
The baling flap pressure is too
high.
Switch off the PTO shaft.
Check the pressure limiting valve for crop blockage.
Replace the pressure sensor.
522016-
Flywheel brake
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
The flywheel brake is applied
when the KMC starts.
Release the flywheel brake.
522017-
Bale chute
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
In "road travel" mode the bale
chute is down.
Raise the bale chute.
522018-
Bale chute
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
When the universal shaft is ro-
tating, the bale chute is up.
Lower the bale chute.
522019-
S5
Momentary switch "Raise bale chute"
Possible cause
Remedy
FMI 2: The data is not permitted.
The momentary switch is
sticking.
Eliminate the cause of the momentary switch sticking.
Replace the momentary switch.
522020-
S6
Momentary switch "Lower bale chute"
Possible cause
Remedy
FMI 2: The data is not permitted.
The momentary switch is
sticking.
Eliminate the cause of the momentary switch sticking.
Replace the momentary switch.
522021-
LR>MAX
Total baling force