![Krone BiG Pack 870 HDP XC Скачать руководство пользователя страница 306](http://html1.mh-extra.com/html/krone/big-pack-870-hdp-xc/big-pack-870-hdp-xc_original-operating-instructions_2004796306.webp)
22
Malfunction, cause and remedy
22.1
Malfunction in the electrics/electronics
306
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
Possible cause
Remedy
The wiring of the actuator is
faulty.
Check actuator and wiring for damage,
.
522308-
K09
Actuator K09 “Release baling flaps“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522309-
K25
Actuator K25 “Baling flaps rapid traverse“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522310-
K11
Actuator K11 “Pressure limiting valve baling flaps“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522311-
K03
Actuator K03 “Bale chute plunger surface“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522312-
KM7
M1