6.5
Section 6
Lubrication System
6
3. Torque the switch to
10.1 N·m (90 in. lb.)
.
Testing
Compressed air, a pressure regulator, pressure gauge,
and a continuity tester are required to test the switch.
1. Connect the continuity tester across the blade
terminal and the metal case of the switch. With
0 psi
pressure applied to the switch, the tester
should indicate
continuity (switch closed)
.
2. Gradually increase the pressure to the switch.
As the pressure increases through the range of
7-11 psi
the tester should indicate a change to
no continuity (switch open)
. The switch should
remain open as the pressure is increased to
90 psi
maximum
.
3. Gradually decrease the pressure through the
range of
7-11 psi
. The tester should indicate a
change to
continuity (switch closed) down to
0 psi
.
4. Replace the switch if it does not operate as
speci
fi
ed.