3-8
[
]
3.2.3
CHECKING FUEL LEVEL AND REFUELING
REFUELING
• Never use the oil other than diesel fuel as fuel. Check the fuel type again before refueling.
• Be sure to stop the engine before refueling.
• Do not overflow fuel while refueling. Wipe off spilled fuel completely.
When getting on and off the machine, use the steps and handrails to prevent yourself from falling down or off from
the machine.
• Be careful not to refuel the tank to a level more than necessary (to the top end of tank). There is a possibility of
overflowing because the fuel expands as the outside air temperature rises.
• Be sure to use diesel fuel as fuel, which meets the standard of each country. To achieve a good fuel efficiency
and exhaust gas property, the engine of this machine uses the electronically controlled fuel injector.
Because this device requires high parts precision and high lubricating ability, when low viscosity fuel with low
lubricating ability is used, the durability may decrease significantly.
3
1
2
4
1.
Check the monitor for the fuel level.
After turning the starter switch to "ON", the fuel level
meter is displayed. When the fuel level is low, the
pointer points E.
2.
Refuel only after stopping the engine.
3.
Remove rubber cover (3), if equipped, from the filler
port (1) and turn filler cap (2) to open it.
4.
Refuel the machine with strainer (4) attached to the
filler port (1) .
When dirt is adhered on strainer (4), take out
strainer (4), wash it with light oil or clean it by air
blowing, and then attach it to the filler port (1) again.
Fuel tank capacity: 186L(49.1Gal)
5.
After refueling, tighten filler cap (2) securely. Attach
rubber cover (3) according to the orientation of the cap.
Copyright©2020 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2YY00041ZE03] [0701CsCshWbYs]