18-22
SCPI Command Reference
2400 Series SourceMeter
®
User’s Manual
Table 18-11
TRIGger command summary
Command
Description
Default
parameter
SCPI
:INITiate[:IMMediate]
:ABORt
:ARM
[:SEQuence[1]]
[:LAYer[1]]
:COUNt <n>
:COUNt?
:SOURce <name>
:SOURce?
:TIMer <n>
:TIMer?
[:TCONfigure]
:DIRection <name>
:DIRection?
[:ASYNchronous]
:ILINe <n>
:ILINe?
:OLINe <n>
:OLINe?
:OUTPut <name>
:OUTPut?
:TRIGger
:CLEar
[:SEQuence[1]]
:COUNt <n>
:COUNt?
:DELay <n>
:DELay?
:SOURce <name>
:SOURce?
Initiate source-measure cycle(s).
Reset trigger system. Goes to idle state.
Path to program Arm Layer:
Specify arm count (1 to 2500 or INFinite).
Query arm count (INFinite = +9.9e37).
Specify control source (IMMediate, TIMer,
MANual, BUS, TLINk, NSTest, PSTest, or
BSTest).
Query control source.
Set timer interval in seconds (0.001 to
99999.99).
Query timer interval.
Enable (SOURce) or disable (ACCeptor)
bypass.
Query state of bypass.
Configure output triggers:
Select input trigger line (1, 2, 3, or 4).
Query input trigger line.
Select output trigger line (1, 2, 3, or 4).
Query output trigger line.
Output trigger (TENTer, TEXit, or NONE).
Query arm output trigger status.
Path to program Trigger Layer:
Clear any pending input triggers immediately.
Specify trigger count (1 to 2500).
Query trigger count.
Specify trigger delay: 0 to 999.9999 (sec).
1
Query source delay.
Specify control source (IMMediate or TLINk).
Query control source.
1
IMMediate
0.1
ACCeptor
1
2
NONE
1
0
IMMediate
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
1. For the Model 2430 Pulse Mode, trigger delay is not used. This command is ignored.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание SourceMeter 2400
Страница 508: ...A Specifications Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 520: ...B StatusandErrorMessages Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 530: ...C DataFlow Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 534: ...D IEEE 488BusOverview Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 554: ...F ContactCheckFunction Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 574: ...G GPIB488 1Protocol Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 589: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 591: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 592: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...