Query
:TRIGgered?
Query triggered amplitude for fixed source
:TRIGgered? DEFault
Query *RST default amplitude
:TRIGgered? MINimum
Query lowest allowable amplitude
:TRIGgered? MAXimum Query highest allowable amplitude
Description
This command performs the same as the [:IMMediate][:AMPLitude]
command except that the amplitude is not updated immediately.
With this command, the amplitude is updated when the SourceMeter is
triggered to perform a source-measure operation. For example, if the
instrument is waiting in the trigger layer for an external trigger, the
amplitude of the source will not update until that external trigger is
received by the SourceMeter. See
Section 11
, “
Trigger models
,” for
details on trigger model operation.
The MINimum and MAXimum parameters are only valid if the highest
source range is presently selected. Sending the MINimum or
MAXimum parameters on a lower source range will generate error -221
(Setting Conflict).
Set voltage limit
[:LEVel] <n>
:SOURce[1]:VOLTage:PROTection[:LEVel] <n>
Set voltage limit for V-Source
Parameters
2400
<n> =
-210 to 210
Specify V-Source limit
20
Set limit to 20V
40
Set limit to 40V
60
Set limit to 60V
80
Set limit to 80V
100
Set limit to 100V
120
Set limit to 120V
160
Set limit to 160V
161 to 210
Set limit to NONE
NONE
Set limit to 210V
DEFault
Set limit to 210V (NONE)
MINimum
Set limit to 20V
MAXimum
Set limit to 210V (NONE)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание SourceMeter 2400
Страница 508: ...A Specifications Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 520: ...B StatusandErrorMessages Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 530: ...C DataFlow Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 534: ...D IEEE 488BusOverview Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 554: ...F ContactCheckFunction Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 574: ...G GPIB488 1Protocol Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 589: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 591: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 592: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...