background image

OPERATION & MAINTENANCE GUIDE

   KI 9600 Series

             Power Meter

                                   KI 9800 Series 

                                              Light Source

     

                                                      
                                                       

Summary of Contents for KI 9600A-Ge

Page 1: ...OPERATION MAINTENANCE GUIDE KI 9600 Series Power Meter KI 9800 Series Light Source...

Page 2: ...C 60529 2001 EN 60529 1993 A1 2003 Degrees of protection provided by enclosures Power Meter conforms to IEC 61315 2005 Calibration of fibre optic power meters EMC Limit IEC 61326 2002 EN 61326 1 1997...

Page 3: ...this instrument which has been engineered to provide the best possible reliability convenience and performance To get the best use from your equipment and ensure its safe operation please spend a few...

Page 4: ...wer 10 Optical Connector 11 Operation 13 TamperLock Mode 16 Autotest Mode 17 Care of your Instrument 18 Accuracy Considerations 19 Definition of Terms 21 Specifications 22 Ordering Information 26 Cali...

Page 5: ...KI 9000 UM 10 3 KI9600A Series Optical Power Meter and KI9800 Series Optical Light Source...

Page 6: ...ations support Instrument Service Qualified personnel must perform adjustment maintenance or repair of this product To obtain service please contact your local Kingfisher International distributor or...

Page 7: ...to 3 mm active area including MPO MTP connectors with up to 72 fibers Detector options include Germanium Ge Indium Gallium Arsenide InGaAs Silicon Si high power large area and wavelength selective Pow...

Page 8: ...otation APC interface option proper interchangeable connector adaptors wider variety of laser options tone options that work with a clip on fiber identifier Light sources have re connection repeatabil...

Page 9: ...and met CAUTION The CAUTION sign denotes a hazard It calls attention to an operating procedure or the like which if not correctly performed or adhered to could result in damage to or destruction of p...

Page 10: ...trument WARNING Observe optical safety when using high power Optical safety requirements at high power levels MUST be observed or eye damage is likely Organisations and users operating optical equipme...

Page 11: ...1 1 95 mW 650 nm class 2M 10 mW 650 nm Class 1 1 95 mW 850 nm class 1 3 88 mW 1310 nm class 1 25 8 mW 1490 1550 1625 nm class 1 10 2 mW Maximum permissible CW output power 21 CFR 1040 10 1995 635 nm...

Page 12: ...20 hours of use To save energy the instrument automatically turns off after 10 minutes without operation To change the batteries open the cover of the battery compartment at the side of the instrumen...

Page 13: ...with a glass fiber end Power Meter Power meter can be used with both PC and APC connector styles Bare fiber adaptors must achieve fiber eccentricity of 100 microns and end tolerance of 300 microns rel...

Page 14: ...herefore it will not wear and only needs occasional cleaning To clean first remove the connector adaptor to access the glass interface then use a soft brush alcohol air can or sticky material such as...

Page 15: ...and the source power is taken as a reference To scroll wavelength press or The display shows the nominal wavelength in nm on the top right of the display To toggle logarithmic relative linear display...

Page 16: ...ne detection In this mode Autotest and tone detection are disabled and measurement integration time is extended In SlowMode the display will show average optical power of the modulated signal The mete...

Page 17: ...on the left hand side To scroll wavelength press or The mode of operation described below is typically used to perform continuity testing with the test tone generator Modulation is active only while...

Page 18: ...this is maintained the instrument is locked into this mode It s possible for a user to end escape this mode maybe they have changed work sites etc To re apply the mode requires adding another PIN cod...

Page 19: ...wavelength selective elements stop some wavelengths from transmitting The meter will detect and show whatever wavelengths are successfully received Instrument compatibility Any Kingfisher Autotest sou...

Page 20: ...waterproof If moisture gets into the instrument dry it out carefully before using it again Where possible keep instrument away from direct sunlight Clean the instrument case using alcohol or other non...

Page 21: ...measuring from 660 to 1550 nm Ge meters offer adequate accuracy for many field users For better accuracy or linearity at wavelengths from 1000 1550 nm or wavelengths above 1550 nm the InGaAs meter is...

Page 22: ...1000 1100 1200 1300 1400 1500 1600 1700 Relative Responsivity A W Wavelength nm Normalized Power Meter Response Uncertainty due to 30 nm tolerance Si Ge 25 C Ge 0 C InGaAs 850 0 10 0 40 0 40 1 3 1300...

Page 23: ...e end of a reference cable Short Long Term Power Stability in CW mode the uncertainty of the power level observed over a given time compared to the mean power during this time Measured with an averagi...

Page 24: ...0 4 lb Shipping 0 5 Kg 1 1 lb Operating Storage 15 to 55 C 25 to 70 C Power 2 alkaline AAA cells Case Polycarbonate 2 5 meter drop tested Calibration Performed without opening instrument Recommended c...

Page 25: ...yp 2 C after warm up Stability over temp dB 0 6 0 6 0 6 0 6 N A N A 0 8 0 35 0 35 Typical over temperature initial tolerance nm 20 20 20 20 5 5 20 NA 5 At 25 C width nm 3 3 3 3 3 3 1 NA 20 FWHM typica...

Page 26: ...3 H5 InGaAs 800 1700 25 850 1300 1310 1390 1490 1550 1590 1610 1625 15 50 30 40 0 02 2 0 09dB 0 005 0 3 0 03 Ge 600 1650 15 635 650 660 780 1610 1625 850 1300 1310 1390 1490 1550 10 60 40 50 0 04 2 0...

Page 27: ...ibration Accuracy2 Polarisation Sensitivity dB Total Uncertainty dB Sensitivity5 30 nm dB 5mm Ge 600 1650 15 635 650 660 780 1610 1625 850 1300 1310 1390 1490 1550 10 35 10 40 0 04 2 0 005 0 5 0 04 5...

Page 28: ...ue OPT060 Universal 1 25mm OPT084 E2000 LSH green OPT060G SMA 905 906 OPT082 LSA DIN 47256 blue OPT071 LC OPT072 KI 9600XL Series Large Area Optical Power Meter Large Area 5mm Ge Power Meter KI 9600XL...

Page 29: ...ptional interchangeable connector adaptor Optional Accessories for KI 9600 and KI 9600XL Series Option KI9000 Series Accessory Pack OPT148 Option Carry Case for two KI2xxx KI3xxx KI7xxx OPT153 Option...

Page 30: ...9828A APC Instrument Source 850 nm VCSEL KI 9840A Standard Accessories SC connector adaptors QRG 50 m and 62 5 m mandrel wraps LED source only Quality Assurance certificate carry strap soft carry pou...

Page 31: ...re in good working condition To enable calibration mode remove belt clip and anti tamper label at the back of the instrument and insert a 2 54 mm 0 1 pitch programming shunt across pins Manipulation o...

Page 32: ...known offsets at this point or calibrate the meter at the selected wavelength as follows Note this process may not be as accurate as the original factory calibration process Inserting the 2 54 mm 0 1...

Page 33: ...tter power to the required level by pressing MOD to reduce and LEVEL to increase output Press to save new value and to exit To return to factory default setting press Repeat the above process for any...

Page 34: ...test fails any performance test return the instrument to the nearest Sales Service Office for repair Instrument Specification specifications are the performance characteristics of the instrument that...

Page 35: ...Alternative Model Optical Light Source KI9822A KI2400 series KI2800 series Optical Power Meter Optical Attenuator KI9600 InGaAs KI7013B KI2600 series For optional test only Optical Spectrum Analyzer...

Page 36: ...00 dBm Note the attenuator setting in setting 1 of Table 4 If the laser source is not powerful enough to give 10 dBm set the attenuator to 2 5 dB and correct the appropriate values in the test report...

Page 37: ...3 2 Switch on the instruments 3 Set the Optical Power Meter to 1310 nm 4 On Light Source enable the source and set the wavelength to 1310 nm 5 Note the measured power level value in the test report i...

Page 38: ...Test set up for KI 9800 Light Source Short Term Stability Test 2 Set the optical power meter to 1310 nm 3 On Light Source enable the source and set the wavelength to 1310 nm 4 Let the unit warm up for...

Page 39: ...played 6 Choose User and select the type of source to be measured FP for Fabery Perot laser 7 To show the display in linear mode Press Menu Press Amptd on the left side of the display Press Linear on...

Page 40: ...IFICATION TESTS Model Date Serial No Ambient Temperature C Options Relative Humidity Firmware Revision Line Frequency Hz Test Facility Customer Performed by Report No Special Notes Table 2 General Tes...

Page 41: ...ription Model Trace No Calibration Due Date 1 Optical Light Source 2 Optical Power Meter 3 Optical Attenuator 4 5 6 7 8 9 10 Accessories Singlemode Fiber Connector Adaptors Table 3 Equipment Record fo...

Page 42: ...Maximum Specification 0 3 dB of Reference 1 10 00 dBm dB 10 30 dBm dBm 9 70 dBm 2 20 00 dBm dB 20 30 dBm dBm 19 70 dBm 3 30 00 dBm dB 30 30 dBm dBm 29 70 dBm 4 40 00 dBm dB 40 30 dBm dBm 39 70 dBm 5 5...

Page 43: ...ults Maximum Specification 1310 nm 1 00 dBm dBm 1550 nm 1 00 dBm dBm Measurement Uncertainty dB Short Term Stability Test optional 1310 nm dBpp 0 10 dBpp 0 04 dBpp typical 1550 nm dBpp 0 10 dBpp 0 04...

Page 44: ...l Wavelength Minimum Spec DUT Measurement Results Maximum Spec Centre wavelength 1310 nm 1290 nm nm 1330 nm 1550 nm 1530 nm nm 1570 nm Spectral Bandwidth FWHM 1310 nm nm 6nm 3 nm typical 1550 nm nm 6n...

Page 45: ...top start display update press HOLD To set reference press and hold Set Ref for more than 3 sec When in reference mode the reference value is shown on the left hand side of the display To display max...

Page 46: ...elength dB dBm mW Hold min max and SlowMode settings To start TamperLock Mode press and hold then press and hold HOLD When display show codE enter six key sequence all keys other than POWER can be use...

Page 47: ...the left hand side Do not enable a laser when there is no fibre attached to the optical output connector To scroll wavelength press or ToneMode Modulation is active only while the source emitter is e...

Page 48: ...ng LEVEL for 5 seconds Display will show codE Enter 6 key sequence using any keys except POWER Triple beep and LOut on display will indicate completion To cancel your entry before completion press POW...

Page 49: ...livery unless specifically stated in the original purchase contract or agreement This warranty excludes optical connectors or incorrect use Opening the instrument will invalidate the warranty Liabilit...

Page 50: ...KI 9000 UM 10 48 NOTES...

Page 51: ...KI 9000 UM 10 49 NOTES...

Page 52: ...KI 9000 UM 10 50 NOTES...