12 Decommissioning, Storage and Transport
12.1 Decommissioning
This is necessary under the following circumstances:
■ The machine is temporarily not needed.
■ The machine is to be moved to another location.
■ The machine is to be scrapped.
Temporarily decommissioning
1. Switch the machine off and is shut-off all connecting lines.
2. Drain condensate from the condensate drain.
Permanent decommissioning
Precondition the main disconnecting device is switched off,
the switch is locked in the off position,
a check has been made that no voltage is present.
Machine fully vented (no pressure).
1. Drain condensate from the condensate drain.
2. Allow the machine to cool down completely.
3. Drain cooling water from water-cooled machines (option K2).
4. Disconnect all supply lines.
12.2 Storage
Moisture can lead to corrosion, particularly on the surfaces of the machine.
Frozen moisture can damage components such as diaphragms, valves, and gaskets.
Please consult with KAESER if you have questions about appropriate storage and commis‐
sioning.
Precondition Condensate drain and condensate lines are completely empty.
1.
Moisture and frost can damage the machine!
➤ Prevent ingress of moisture and formation of condensation.
➤ Maintain a storage temperature of >32°F.
2. Store the machine in a dry, frost-proof room.
12.3 Transport
12.3.1 Safety
Weight and center of gravity determine the most suitable method of transportation. The center of
gravity is shown in the drawing in chapter 13.1.
12 Decommissioning, Storage and Transport
12.1 Decommissioning
No.: 901760 02 USE
Operator Manual Refrigerated Dryer
TG
77
Содержание TG 450
Страница 2: ...Original instructions KKW DTG 2 02 en Z1 SBA TROCKNER 20221118 115620...
Страница 6: ...Contents iv Operator Manual Refrigerated Dryer TG No 901760 02 USE...
Страница 8: ...List of Illustrations vi Operator Manual Refrigerated Dryer TG No 901760 02 USE...
Страница 10: ...List of Tables viii Operator Manual Refrigerated Dryer TG No 901760 02 USE...