TG 450
TG 520
TG 650
TG 780
TG 980
Weight [lb]
1405 / 1372
1)
1450 / 1418
1)
1555 / 1519
1)
1545 / 1511
1)
1685 / 1650
1)
1)
Option K2
Tab. 5 Weight
2.4 Ambient conditions
TG 450
TG 520
TG 650
TG 780
TG 980
Maximum eleva‐
tion AMSL
1)
[ft]
3000
3000
3000
3000
3000
Permissible ambient tem‐
perature [°F]
38 – 120
38 – 120
38 – 120
38 – 120
38 – 120
1)
Higher altitudes are permissible only after consultation with the manufacturer.
Tab. 6 Ambient conditions
2.5 Compressed air system
TG 450
TG 520
TG 650
TG 780
TG 980
Pressure drop
1)
[psig]
1.45
2.03
1.18
1.89
2.90
Flow rate
1)
[cfm]
1340
1550
1910
2330
3070
Flow rate
1)
[cfm] (Op‐
tion K2)
1589
1836
2190
2684
3355
Cooling air flow rate
[cfm] (Option K1 only)
2940
3880
4180
5000
7360
Heat exchanger volume
[gal]
31.4
31.4
41.5
41.5
41.7
Pressure dew point
1)
[°F]
39
39
39
39
39
Max. working pres‐
sure [psig]
230
230
188
188
188
Min. compressed air inlet
temperature [°F]
38
38
38
38
38
Max. compressed air inlet
temperature [°F]
140
140
140
140
140
1)
According to ISO 7183 Option A2:
■ Reference point: 14.5 psi(a), 68°F, 0% relative humidity:
■ Operating point: Gauge working pressure 100 psig, compressed air inlet temperature 100°F,
100% relative humidity, cooling air inlet temperature 100°F, cooling water inlet temperature
84°F
Tab. 7 Compressed air system
2
Technical Data
2.4
Ambient conditions
6
Operator Manual Refrigerated Dryer
TG
No.: 901760 02 USE
Содержание TG 450
Страница 2: ...Original instructions KKW DTG 2 02 en Z1 SBA TROCKNER 20221118 115620...
Страница 6: ...Contents iv Operator Manual Refrigerated Dryer TG No 901760 02 USE...
Страница 8: ...List of Illustrations vi Operator Manual Refrigerated Dryer TG No 901760 02 USE...
Страница 10: ...List of Tables viii Operator Manual Refrigerated Dryer TG No 901760 02 USE...