2. Carefully insert the control module sensor
3
in the opening
4
of the service unit
1
.
3. Place the snap fastener
5
of the control module
1
into the service unit eyes.
4. Press the control module
2
against the service unit until the snap fastener audibly clicks into
place.
5. At the screw-in part
11
, replace old sealing material with new sealing tape.
6. Install the screw-in part
11
in the service unit
1
.
7. If necessary, insert a new O-ring
10
.
8. Tighten the union nut
13
at the shut-off valve
9
.
9. Install the condensate line.
10. Open the shut-off valve
9
upstream of the condensate drain.
11. Close all access doors, replace and secure all removable panels.
10 Maintenance
10.5 Maintaining the condensate drain
64
Operator Manual Refrigerated Dryer
TG
No.: 901760 02 USE