➤ Attach hoists only to suitable lifting points.
➤ Be aware of the center of gravity to avoid potential tipping.
➤ Make sure the danger zone is clear of personnel.
➤ Do not step onto machine components to climb up the machine.
Installation
A suitable installation location for the machine prevents the potential for accidents and faults.
➤ Install the machine in a suitable compressor room.
➤ Ensure sufficient and suitable lighting such that the display can be read without glare and that
work can be carried out comfortably and safely.
➤ Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance.
➤ If installed outdoors, the machine must be protected from frost, direct sunlight, dust, rain, and
splashing water.
➤ Do not operate in areas in which specific requirements with regard to explosion protection are
in force.
➤ Ensure adequate ventilation.
➤ Place the machine in such a manner that the working conditions in its environment are not im‐
paired.
➤ Comply with limit values for ambient temperature and humidity.
➤ Ensure clean compressed air without damaging components.
Damaging contaminants are for instance: explosive or chemically instable gases and vapours,
acid or base forming substances such as ammonia, chlorine or hydrogen sulfide.
➤ Do not position the machine in the warm exhaust air flow from other machines.
➤ Keep suitable fire extinguishing agents ready for use.
Commissioning, operation and maintenance
During commissioning, operation and maintenance you may be exposed to dangers resulting from,
e.g., electricity, pressure and temperature. Careless actions can cause accidents with severe ad‐
verse effects for your health.
➤ Allow maintenance work to be carried out only by authorized personnel.
➤ Switch off and lock out / tag out the power supply disconnecting device and verify the absence
of voltage.
➤ Check that the floating relay contacts are voltage-free.
➤ Close shut-off valves or otherwise isolate the machine from the compressed air network to en‐
sure that no compressed air can flow back into the machine.
➤ Depressurize all pressurized components and enclosures. Verify the vented state.
➤ Allow the machine to cool down.
➤ Do not open the cabinet while the machine is switched on.
➤ Do not open or dismantle any valves.
➤ Use only spare parts approved by KAESER for use in this machine.
De-commissioning, storage and disposal
Improper handling of old operating fluids and components represent a danger for the environment.
3
Safety and Responsibility
3.5
Dangers
No.: 901760 02 USE
Operator Manual Refrigerated Dryer
TG
17
Содержание TG 450
Страница 2: ...Original instructions KKW DTG 2 02 en Z1 SBA TROCKNER 20221118 115620...
Страница 6: ...Contents iv Operator Manual Refrigerated Dryer TG No 901760 02 USE...
Страница 8: ...List of Illustrations vi Operator Manual Refrigerated Dryer TG No 901760 02 USE...