Cleaning
1. If necessary, have the refrigerant condenser cleaned by an authorized KAESER service repre‐
sentative.
2. Remove and clean the strainer of the dirt trap.
10.5 Maintaining the condensate drain
10.5.1 Checking the condensate drain
Precondition The user's power supply disconnecting device is switched on.
Machine is pressurized.
The
Power
LED lights.
Fig. 32 Checking the condensate drain
1
Power
LED
2
«TEST» key
3
Alarm
LED
1. With one hand, lightly touch the condensate line at the condensate drain.
2. With your other hand, push and hold the «TEST» key at the condensate drain for at least
2 seconds.
Result As soon as the condensate drain opens, you will feel a short burst at the condensate line.
Replace the service unit if you do not experience a burst during manual test.
10.5.2 Replacing the service unit
The condensate drain cannot be cleaned. The service unit must be changed if condensate does
not drain.
Material Sealing tape for sealing the screw-in part
O-ring 16x2 (5.1519.0), if required
10 Maintenance
10.5 Maintaining the condensate drain
62
Operator Manual Refrigerated Dryer
TG
No.: 901760 02 USE