7 Initial Start-up
7.1 Ensuring safety
Here you will find instructions for a safe commissioning of the machine.
Warning instructions are displayed prior to a potentially dangerous task.
Disregarding warning instructions can cause serious injuries!
Complying with safety instructions
Ignoring safety instructions can cause unforeseeable dangers.
➤ Follow the instructions in chapter 3 "Safety and Responsibility".
➤ Commissioning tasks may only be carried out by authorized personnel!
➤ Make sure that no one is working on the machine.
➤ Ensure that all service doors and panels are locked.
Working on live components
Touching voltage carrying components can result in electric shocks, burns, or death.
Dangerous voltages persist at the terminals of the fan motor and intermediate circuit capacitors in
the control cabinet for some time after power is switched off.
➤ Work on electrical equipment may be carried out only by authorized electricians.
➤ Switch off and lock out / tag out the power supply disconnecting device and verify the absence
of voltage.
➤ Before starting work on the control cabinet or the fan, wait at least 5 minutes after the power
supply disconnecting device has been switched off.
➤ Check that the floating relay contacts are voltage-free.
Working on the compressed air network
Compressed air is contained energy. Uncontrolled release of this energy can cause serious injury
or death. The following safety instructions relate to any work on components that could be under
pressure.
➤ Close shut-off valves or otherwise isolate the machine from the compressed air network to en‐
sure that no compressed air can flow back into the machine.
➤ Fully vent all pressurized components and enclosures.
➤ Do not open or dismantle any valves.
Working on the drive system
Touching voltage carrying components can result in electric shocks, burns, or death.
Touching the fan while the machine is switched on can result in serious injury.
➤ Switch off and lock out / tag out the power supply disconnecting device and verify that no volt‐
age is present.
➤ Do not open the cabinet while the machine is switched on.
Further information Information regarding authorized personnel can be found in chapter 3.4.2.
Information regarding dangers and their avoidance can be found in chapter 3.5.
7
Initial Start-up
7.1
Ensuring safety
48
Operator Manual Refrigerated Dryer
TG
No.: 901760 02 USE
Содержание TG 450
Страница 2: ...Original instructions KKW DTG 2 02 en Z1 SBA TROCKNER 20221118 115620...
Страница 6: ...Contents iv Operator Manual Refrigerated Dryer TG No 901760 02 USE...
Страница 8: ...List of Illustrations vi Operator Manual Refrigerated Dryer TG No 901760 02 USE...
Страница 10: ...List of Tables viii Operator Manual Refrigerated Dryer TG No 901760 02 USE...