10-12
Alarms #:
Description:
Causes et verifications
HR8614
UC contactor did not activate.
Verify UC contactor operation, because it did not
activate when the CPU UCA output activated
HR8615
UC contactor has remained closed.
Verify UC contactor operation, because it remained
closed when the CPU UCA output deactivated
HR8700
RCT relay did not activate.
Verify RCT relay operation, because it did not activate
when the CPU RCT output activated
HR8701
RCT relay has remained closed.
Verify RCT relay operation, because it remained closed
when the CPU RCT output deactivated
HR8702
Custom, refer to user manual list.
HR8703
Custom, refer to user manual list.
HR8704
Custom, refer to user manual list.
HR8705
Custom, refer to user manual list.
HR8706
Up direction fast speed valve “U or ULS valve” had activated
when the “U” relay did not activate.
Verify U relay operation.
HR8707
Up direction fast speed valve “U or ULS valve” did not activate
when the “U” relay activated.
Verify U relay operation.
HR8708
Up direction slow speed valve “US or UDS valve” had activated
when the “US” relay did not activate.
Verify US relay operation.
HR8709
Up direction slow speed valve “US or UDS valve” did not
activate when the “US” relay activated.
Verify US relay operation.
HR8710
Down direction fast speed valve “DV or DMS valve” had
activated when the “DV” relay did not activate.
Verify DV relay operation.
HR8711
Down direction fast speed valve “DV or DMS valve” did not
activate when the “DV” relay activated.
Verify DV relay operation.
HR8712
Down direction slow speed valve “DL or DLS valve” had
activated when the “DL” relay did not activate.
Verify DL relay operation.
HR8713
Down direction slow speed valve “DL or DLS valve” did not
activate when the “DL” relay activated.
Verify DL relay operation.
HR8714
UP/DW relay did not activate.
Verify UP/DW relay operation, because it did not
activate when the PLC UP/DW input activated
HR8715
UP/DW relay has remained closed.
Verify UP/DW relay operation, because it remained
closed when the PLC UP/DW input deactivated
HR8800
Communication loss with the JRT-CAN-MAS
Verify connections, supply and switches configuration.
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...