10-10
Alarms #:
Description:
Causes et verifications
HR8405
Custom, refer to user manual list.
HR8406
Custom, refer to user manual list.
HR8407
Custom, refer to user manual list.
HR8408
Custom, refer to user manual list.
HR8409
Custom, refer to user manual list.
HR8410
Custom, refer to user manual list.
HR8411
Corrupted data
CPU’s data are corrupted. Defective CPU or data loss.
HR8412
Custom, refer to user manual list.
HR8413
Custom, refer to user manual list.
HR8414
Custom, refer to user manual list.
HR8415
Custom, refer to user manual list.
HR8500
DZO relay did not activate.
Verify DZO or DZO1 relay operation.
HR8501
DZO relay contacts remained closed.
Verify DZO or DZO1 relay operation.
HR8502
Reserved
HR8503
Reserved
HR8504
Custom, refer to user manual list.
HR8505
Custom, refer to user manual list.
HR8506
LU and LD levelling sensors were activated at the same time.
Verify LU and LD relays operation. Verify the sensor
operation in the top of car reader connecting box
HR8507
INS relay did not activate.
Verify INS relay operation, because it did not activate
when the CPU INS input activated
HR8508
INS relay has remained closed.
Verify INS relay operation, because it remained closed
when the CPU INS input deactivated
HR8509
HDC relay did not activate.
Verify HDC relay operation, because it did not activate
when the CPU HDC input activated
HR8510
HDC relay has remained closed.
Verify HDC relay operation, because it remained closed
when the CPU HDC input deactivated
HR8511
CDC relay did not activate.
Verify CDC relay operation, because it did not activate
when the CPU CDC input activated
HR8512
CDC relay has remained closed.
Verify CDC relay operation, because it remained closed
when the CPU CDC input deactivated
HR8513
BAC relay did not activate.
Verify BAC relay operation, because it did not activate
when the CPU BAC input activated
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...