10-13
Alarms #:
Description:
Causes et verifications
(See CANBUS manual)
HR8801
Communication loss with the JRT-CAN-HCI
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8802
Communication loss with the Car B duplex
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8803
Communication loss with the module 0 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8804
Communication loss with the module 1 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8805
Communication loss with the module 2 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8806
Communication loss with the module 3 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8807
Hall network was opened
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8808
Communication loss with the module 4 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8809
Communication loss with the module 5 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8810
Communication loss with the module 6 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8811
Communication loss with the module 7 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8812
Light curtain fault.
For a vertical sliding door freight elevator, the photocell
proper functioning must be checked before closing the
door. Check the photocell proper functioning.
HR8813
Custom, refer to user manual list.
HR8814
Custom, refer to user manual list.
HR8815
Door jammed on opening.
The elevator tried to completely open the door 3 times
without succeeding. The alarm activates once an
opening relay (FOP, ROP) is activated lasting more
than the protection delay. Ensure the door operators are
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...