6-1
6. OPERATION PRINCIPLE FOR CAR ZONING AND LEVELLING:
6.1.
WITH A STANDARD TAPE SELECTOR: (IP8300 W6 LULA):
6.1.1. Installation of the standard tape
The setup of a tape selector replaces the PM switches and the vanes in the hoistway and also the
cam and the reed switches on the car.
The steel tape is installed in the hoistway and is composed of three rows of magnets; one for door
zone and leveling, one for hoistway access, the other one is not used. The sensing head is located
on the car and has three rows of sensors that are sensible to "North" or "South" magnets. Four
sensors (North) detect the left row of magnets: LU sensor for up leveling, LD sensor for down
leveling and DZO-DZO1 sensors for door zoning. One sensor (North) detects the right row of
magnets: P1 sensor for the hoistway access travel.
The sensors can be moved inside the sensing head to facilitate the adjustment of the car
positioning. For example, in order to achieve the best possible leveling adjustment, it is better and
easier to move the LU and LD sensors than to cut off the magnet on the steel tape.
P1 (North Magnet)
LU (North Magnet)
DZO (North Magnet)
DZO1 (North Magnet)
P2 (North Magnet)
LD (North Magnet)
Sensing Head IP8300
Internal view of magnet
1
2
3
Row
LD (Down Leveling)
P2 (Unused)
DZO1 (Door Zone)
DZO (Door Zone)
LU (Up Leveling)
P1 (Displacement control in access)
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...