6-2
It is strongly recommended not to stick the magnets immediately to the steel tape. If a mistake
should happen in the positioning, it would still be easy to move the magnets on the tape. Wait
until you have made successful tests before sticking definitely the magnets to the tape.
•
Door zone (DZO), 7” North magnet and levellers (LU and LD):
▪
Physically position the car perfectly in level with the landing
▪
Mark with a pencil on the tape at the location that corresponds to the center of the
2 sensors "DZO" and "DZO1" on the side of the head reader.
▪
Lower or raise the car.
▪
Position the row guide to locate row 1 of the tape.
▪
Install the "DZO" magnet.
▪
Physically position the car level with the landing, and confirm that the DZO
magnet is centered between LU and LD. The DZO input should be active, and LU
and LD must be inactive.
Repeat for other floor
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...