8-30
8.2.15.
How to change displayed values for each floors on a microcomm or
Canbus PI.
If you use a Microcomm or Canbus PI, you can easily change the displayed name for each floor.
To do so you will have to change the appropriate DM through the LCD screen of the controller.
DMs 0452 to 0481 are used to define which characters are displayed. Each floor can display up to
4 digits. The following table shows you how each DM relates to each digit of each floor:
DM Register
Modified digits
DM0452
Bottom floor (BZ) digit 3 and 4 (xx34)
DM0543
Bottom floor (BZ) digit 1 and 2 (12xx)
DM0454
2
nd
floor (2Z) digit 3 and 4 (xx34)
DM0455
2
nd
floor (2Z) digit 1 and 2 (12xx)
…
…
DM0480
15
th
floor (15Z) digit 3 and 4 (xx34)
DM0481
15
th
floor (15Z) digit 1 and 2 (12xx)