6-13
6.2.8. DZO/DZO1 signals configuration
The circuit, situated in the top of car junction box, offers 4 options for DZO and
DZO1 signals (see Fig. 12).
Option #1: Allows separating the DZO and DZO1 signals in two distinct negative
signals (COM).
Option #2: Allows separating the DZO and DZO1 signals in two distinct positive
signals (+).
Option #3: Allows putting the DZO and DZO1 signals in serial and the output
signal is on the DZO terminal. The signal is negative (COM).
Option #4: Allows putting the DZO and DZO1 signals in serial and the output
signal is on the DZO terminal. The signal is positive (+).
NOTE: OPR is the common for all signals. Put OPR to (COM) to have negative
signals or put OPR to (+) to have positive signals.
FIG. 12
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...