10-8
Alarms #:
Description:
Causes et verifications
indicators operation on the processor (they should be
flashing when the elevator is moving). Clean both
infrared transmitters and the hoistway mirror.
HR8201
Servo valve failure (EMV from Maxton, LRV from Bucher …
refer to drawings)
After 3 attempts to reset the servo valve (in 2 minutes),
the elevator is shut down. To restore normal operation
mode, cycle the power or press the manual reset button.
Refer to the servo valve user manual to access the error
list.
HR8202
Servo valve following error (EMV from Maxton, LRV from
Bucher … refer to drawings)
If the problem occurs in the « up » direction, a lowering
sequence will be initiate.
If the problem occurs in the « down » direction, the
movement in the « down » direction will be not
allowed, but calls above the car position will be
authorized.
If the problem occurs in both directions, the elevator is
shut down and a manual reset is required.
Refer to the servo valve user manual to access the error
list.
HR8203
Custom, refer to user manual list.
HR8204
Uncontrolled elevator speed.
Check functioning of valves relays U, US, DV and DL
HR8205
Custom, refer to user manual list.
HR8206
Custom, refer to user manual list.
HR8207
Custom, refer to user manual list.
HR8208
The elevator moved in the wrong direction
Ensure the motor and valves are functioning properly
according to the car's direction. Ensure the contactor's
are correctly activating. Ensure the perforated tape
counter is properly functioning and increment
appropriately (see DM5800).
HR8209
Car door contact CDC relay opened during movement out of door
zone.
Verify CDC contacts operation and clean them.
HR8210
Hall door contact HDC relay opened during movement out of Verify HDC contacts operation and clean them. This
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...