NOTES AND PRECAUTIONS
•
The controller must be installed by competent people who possess the suitable training and cards for
the installation of elevator controllers;
•
The controller’s power supply must come from a fuse switch supplied by others. The fuses value must
respect the electrical code;
•
It is necessary to install a separate conductive element to ground the controller in the mechanical
room. To know the size of the conductive element, check the electrical code. An indirect grounding
(e.g. water pipes) may cause intermittent troubles and electrical noises may occur;
•
The controller contains electrostatic sensitive devices. Before handling a component, it’s necessary to
touch a grounded metal object (GND) to avoid an electrostatic discharge on it.
•
To avoid problems caused by transportation and handling, check and tighten all the points of
connections on the side "power"; from main power supply of the controller to the motor;
•
Please note the controller comes with a one (1) year guarantee, effective on the day of billing. An
improper use of the controller, an incorrect connection or the disregard of the user’s manual may void
the guarantee. Also note that only the components are guaranteed;
•
In case of an incorrect connection, the controller is protected by TVS which can short-circuit. Verify
the functioning and replace them if needed.
Operating conditions:
•
The 3 phases entry voltage may vary by more or less 10 %;
•
A 60HZ frequency is standard, a 50HZ frequency is available on special order;
•
The operating temperature is 0 to 45°C (32 to 113°F);
•
The relative humidity is 95 % (noncondensing);
•
Do not install the NEMA 1 standard enclosure in a dusty environment or where there is risk of water
infiltration. Other types of enclosures are available upon request (NEMA 4, 12 etc.);
•
Please contact Automatisation JRT Inc. if the motor is installed at 50 ft. or more from the controller;
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...