8-29
8.2.12.
Hydraulic cylinder reset sequence:
OPTION
DESCRIPTION
UNIT
DM
TELES.
CYLINDERS
RESET SEQUENCE
Activation of the cylinders reset sequence.
YES/NO
0375
DAY (0 = SUN, 7 =
EVERY DAYS)
Reset sequence days selection.
(0= Sunday, 1= Monday, 2= Tuesday, 3=
Wednesday, 4= Thursday, 5= Friday, 6=
Saturday, 7= Every days of the week)
0 to 7
0376
1st RESET
(HH:MM)
First reset sequence time.
HH:MM
0397
2nd RESET
(HH:MM)
Second reset sequence time.
(Write 9999 to deactivate the second reset)
HH:MM
0398
START SEQ. DELAY
WITHOUT SU/SD DIR.
Once the first or the second reset time period is
reached, this is the delay without any direction
the sequence will initiate the bottom floor
return.
0.1s
0387
SEQ. CANCEL DEL. IF
NOT STARTING
Protection delay to turn off the reset sequence if
the elevator did not start moving to bottom
floor.
Minutes
0389
SYNCHRO SEQUENCE
OPERATION TIME
Duration of the lowering down of the car on the
buffers. (Between 5 and 120 seconds)
0.1s
0388
SYNCHRO SEQ MAN.
ACTIVATION (TEST)
Manual activation of the reset sequence for
immediate testing.
OUI/NON
0390
8.2.13.
Blue code/Free car sequence:
OPTION
DESCRIPTION
UNIT
DM
N/A
8.2.14.
Other Parameters:
OPTION
DESCRIPTION
UNIT
DM
NB STARTS BEFORE
FAULTS RESET
This value represents the number of starts in
automatic mode before the alarm buffer list
will be reset. Channels HR80 to HR88 will
be erased. That number should be kept not
too high for the proper operation of the
alarm history list (20 to 25 normally).
n/a
0275
INVERT CAR STOP
SWITCH INPUT SA
Reverse or not the car stop switch input.
YES/NO
0258
INVERT
LOAD
WEIGHT INPUTS
Reverse or not the 3 load weight inputs
Lw1, Lw2, Lw3. Some load weight system
outputs are reversed.
YES/NO
0279
DEACTIVATE
BAR
CODE P1, P2, P3.
Deactivate the bar code sensors. This is for
temporary bar code failure. The elevator will
run and LRH and LRB will correct the
position at bottom and top floor. Once the
problem is resolved, put NO to activate the
bar code system.
YES/NO
0029
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...