4-1
4. FINAL START-UP:
A.
Be sure that all sections of the temporary start-up are done.
B.
Proceed to the installation and the mechanical adjustment of the slowdown limits (Standard Tape
Selector: section 6.1.2).
C.
Proceed to the adjustment of the Selector Tape (Standard Tape Selector: section 6.1)
D.
Adjust the hoistway access travelling limits (Standard Tape Selector: section 6.1.3).
E.
If the elevator is provided with a low oil level sensor, its must be configure regarding the type of
contact use (See section 8.2.1). (To reset a low oil level signal, press the “MANUAL RESET”
button or cycle the inspection switch off-on).
F.
If there is thermistor relay TUS, it must be reset (red light off). See chapter 3, step H.
G.
If the controller has a thermal contact "CT" it must be connect. (See section 8.2.1 for
configuration).
H.
Overload relay "RS1" must be reset.
•
If Across the Line or Star-Delta starter: Reset it by pressing the reset buton on the "RS1" relay
•
If Solid-State starter (
Benshaw
): Reset fault relay (FLT) by pressing Parameter & Up buttons
simultaneously on the circuit board.
•
If Solid-State starter (
SSchuh
): Reset fault by pressing « Push to reset » buttons on
the soft-start.
I.
Proceed to all tests and adjustments described in sections 7.
J.
Put the elevator in "maintenance" mode using the controller’s switch. Put the inspection switch to
"NORMAL". It is now possible to place car calls without the doors opening.
To reset all the alarms (2 different ways):
➢
Hold for 2.5 seconds the « MANUAL RESET » button on the controller inspection board to
reset the controller and clear the alarms. The controller will be rearmed only if all
conditions are ok.
➢
By using the LCD, erase the alarms and then consult the alarms list to check that there are
no more. (Section 1 for use of the LCD).
WARNING
CPU inputs are designed to operate at 24VDC. DANGER: Never apply 120VAC for it may cause
severe damage to the inputs.
On reception of the controller, the COM terminal is grounded.
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...