6-11
Magnets required for the binary code
Binary
code
P1
P2
P3
Nbr.
Length
(inches)
Floors
1
1
2 ¼
2
1
2 ¼
3
2
2 ¼
4
1
2 ¼
5
2
2 ¼
6
2
2 ¼
7
3
2 ¼
•
At the lower level, the code 1 "P1" is not required if the "LRB" limit is installed.
•
At the higher level, the code XX is not required if the "LRH" limit is installed.
When the DZO magnets are finally stuck, use the provided template to stick the
barcode magnets at each floor (Fig.11)
FIG. 11
The binary code is only validated when the sensors are activated and the elevator is
centered to the floor (DZO = ON, LU = OFF, LD = OFF). These magnets allow
correcting the elevator's position it is thus important to correctly place them.
IMPORTANT
In duplex, triplex and other groups, if the elevator doesn't reach the lower levels,
the barcode must begin at the same level as the car calls.
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...