8-25
8.2.5. Encoder/Perforated tape:
OPTION
DESCRIPTION
UNIT
DM
DECEL
DISTANCE
SPD <= 225FPM
Number of holes counted to slow down the
elevator. In general, this is the slow down
distance for 1 floor run. If the car contract
speed is 200 FPM and less, this is the only
slow down distance used. On a 250 FPM
job, most of the time; this is the 1 floor run
slowdown distance.
¾ inch
0132
DECEL
DISTANCE
SPD >= 250FPM
Number of holes counted to slow down the
elevator. This is the slow down distance for
2 floor run and more.
¾ inch
0133
BOT
ACCES
ZONE
LIMIT (3/4 CNT)
Number of holes counted to determine the
access came at bottom floor.
¾ inch
0255
TOP
ACCES
ZONE
LIMIT (3/4 CNT)
Number of holes counted to determine the
access came at top floor.
¾ inch
0256
FORCE NEW LEVEL
MANUALLY 2-TOP
This option allows forcing a specific floor
level to put the car out of step. This feature
is useful to make a buffer test or to verify the
speed limiting device system at final floors.
n/a
0026
8.2.6. Door timers & options:
OPTION
DESCRIPTION
UNIT
DM
DOOR
OPENED
DEL.ON HALL CALL
Door opened time on a hall call. The timer
begins to count when the door is fully opened.
0.1s
0000
DOOR
OPENED
DEL.ON CAR CALL
Door opened time on a car call. The timer
begins to count when the door is fully opened.
0.1s
0001
DOOR
OPENED
DEL.ON
PH
RE-
OPENING
Door opened time on photocell re-opening. The
timer begins to count when the door is fully
opened
0.1s
0002
DELAY BEFORE DOOR
NUDGING
Time before door nudging when the photocell
reopens the door. The timer begins to count
when the door is fully opened. The door will
close in reduce speed. Normally 15s.
0.1s
0066
DOOR
PRE-OPENING
IN LEVELING ZONE
Door pre-opening when the elevator slows down
and the door zone sensor activates in levelling.
YES/NO
0080
DELAY BEFORE DOOR
PRE-OPENING
When the elevator slows down and the door
zone sensor activates in levelling, this is the
delay before the door begins to open. Adjust that
delay long enough to see around 1.0 inch when
door is 75% opened.
0.1s
0088
MAIN FLOOR DOOR
OPENED DELAY LW3
Activation of the longer door opened timer at
main floor. This timer only at main floor and as
the effect to load more the elevator cabin before
the door closure. That feature is more often used
in groups. Not in simplex car.
YES/NO
0092
MAIN FLOOR DOOR
OPENED DELAY LW3
That delay takes effect when the longer door
opened timer at main floor is activated. The
weight sensor (LW3) input is generally adjusted
for 25% load. As soon as that input turns on, the
door begins to close. The door close button is
0.1s
0173
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...