6-12
Example: Car calls for elevator "B" of a duplex begin at 3Z. The barcode must
begin at level 3 thus P1 and P2 activated.
6.2.6. Electric installation of the selector tape
The selector tape's electric junction box possesses a connector permitting the entry of
electric wires (see photo 1).
PHOTO 1
6.2.7. Tape selector electrical connection
The selector tape is supplied +24 VDC from between terminals "+V" and "COM".
The board is protected by a 1 amp fuse and a 33 Volts TVS. The maximum electric
consumption is 300 mA (see photo 2).
PHOTO 2